Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Pharmaceutics ; 16(3)2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38543271

RESUMEN

Peri-implantitis is a growing pathological concern for dental implants which aggravates the occurrence of revision surgeries. This increases the burden on both hospitals and the patients themselves. Research is now focused on the development of materials and accompanying implants designed to resist biofilm formation. To enhance this endeavor, a smart method of biofilm inhibition coupled with limiting toxicity to the host cells is crucial. Therefore, this research aims to establish a proof-of-concept for the pH-triggered release of chlorhexidine (CHX), an antiseptic commonly used in mouth rinses, from a titanium (Ti) substrate to inhibit biofilm formation on its surface. To this end, a macroporous Ti matrix is filled with mesoporous silica (together referred to as Ti/SiO2), which acts as a diffusion barrier for CHX from the CHX feed side to the release side. To limit release to acidic conditions, the release side of Ti/SiO2 is coated with crosslinked chitosan (CS), a pH-responsive and antimicrobial natural polymer. Scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM/EDX) and Fourier transform infrared (FTIR) spectroscopy confirmed successful CS film formation and crosslinking on the Ti/SiO2 disks. The presence of the CS coating reduced CHX release by 33% as compared to non-coated Ti/SiO2 disks, thus reducing the antiseptic exposure to the environment in normal conditions. Simultaneous differential scanning calorimetry and thermogravimetric analyzer (SDT) results highlighted the thermal stability of the crosslinked CS films. Quartz crystal microbalance with dissipation monitoring (QCM-D) indicated a clear pH response for crosslinked CS coatings in an acidic medium. This pH response also influenced CHX release through a Ti/SiO2/CS disk where the CHX release was higher than the average trend in the neutral medium. Finally, the antimicrobial study revealed a significant reduction in biofilm formation for the CS-coated samples compared to the control sample using viability quantitative polymerase chain reaction (v-qPCR) measurements, which were also corroborated using SEM imaging. Overall, this study investigates the smart triggered release of pharmaceutical agents aimed at inhibiting biofilm formation, with potential applicability to implant-like structures.

2.
Tech Mess ; 90(12): 761-785, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38046181

RESUMEN

This review provides an overview on bio- and chemosensors based on a thermal transducer platform that monitors the thermal interface resistance R th between a solid chip and the supernatant liquid. The R th parameter responds in a surprisingly strong way to molecular-scale changes at the solid-liquid interface, which can be measured thermometrically, using for instance thermocouples in combination with a controllable heat source. In 2012, the effect was first observed during on-chip denaturation experiments on complementary and mismatched DNA duplexes that differ in their melting temperature. Since then, the concept is addressed as heat-transfer method, in short HTM, and numerous applications of the basic sensing principle were identified. Functionalizing the chip with bioreceptors such as molecularly imprinted polymers makes it possible to detect neurotransmitters, inflammation markers, viruses, and environmental pollutants. In combination with aptamer-type receptors, it is also possible to detect proteins at low concentrations. Changing the receptors to surface-imprinted polymers has opened up new possibilities for quantitative bacterial detection and identification in complex matrices. In receptor-free variants, HTM was successfully used to characterize lipid vesicles and eukaryotic cells (yeast strains, cancer cell lines), the latter showing spontaneous detachment under influence of the temperature gradient inherent to HTM. We will also address modifications to the original HTM technique such as M-HTM, inverted HTM, thermal wave transport analysis TWTA, and the hot-wire principle. The article concludes with an assessment of the possibilities and current limitations of the method, together with a technological forecast.

3.
Adv Sci (Weinh) ; 9(24): e2200459, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35780480

RESUMEN

Despite the importance of cell characterization and identification for diagnostic and therapeutic applications, developing fast and label-free methods without (bio)-chemical markers or surface-engineered receptors remains challenging. Here, we exploit the natural cellular response to mild thermal stimuli and propose a label- and receptor-free method for fast and facile cell characterization. Cell suspensions in a dedicated sensor are exposed to a temperature gradient, which stimulates synchronized and spontaneous cell-detachment with sharply defined time-patterns, a phenomenon unknown from literature. These patterns depend on metabolic activity (controlled through temperature, nutrients, and drugs) and provide a library of cell-type-specific indicators, allowing to distinguish several yeast strains as well as cancer cells. Under specific conditions, synchronized glycolytic-type oscillations are observed during detachment of mammalian and yeast-cell ensembles, providing additional cell-specific signatures. These findings suggest potential applications for cell viability analysis and for assessing the collective response of cancer cells to drugs.


Asunto(s)
Células Eucariotas , Saccharomyces cerevisiae , Animales , Glucólisis , Mamíferos , Saccharomyces cerevisiae/metabolismo
4.
J Colloid Interface Sci ; 585: 583-595, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33127054

RESUMEN

Understanding microbial adhesion and retention is crucial for controlling many processes, including biofilm formation, antimicrobial therapy as well as cell sorting and cell detection platforms. Cell detachment is inextricably linked to cell adhesion and retention and plays an important part in the mechanisms involved in these processes. Physico-chemical and biological forces play a crucial role in microbial adhesion interactions and altering the medium ionic strength offers a potential means for modulating these interactions. Real-time studies on the effect of ionic strength on microbial adhesion are often limited to short-term bacterial adhesion. Therefore, there is a need, not only for long-term bacterial adhesion studies, but also for similar studies focusing on eukaryotic microbes, such as yeast. Hereby, we monitored, in real-time, S. cerevisiae adhesion on gold and silica as examples of surfaces with different surface charge properties to disclose long-term adhesion, retention and detachment as a function of ionic strength using quartz crystal microbalance with dissipation monitoring. Our results show that short- and long-term cell adhesion levels in terms of mass-loading increase with increasing ionic strength, while cells dispersed in a medium of higher ionic strength experience longer retention and detachment times. The positive correlation between the cell zeta potential and ionic strength suggests that zeta potential plays a role on cell retention and detachment. These trends are similar for measurements on silica and gold, with shorter retention and detachment times for silica due to strong short-range repulsions originating from a high electron-donicity. Furthermore, the results are comparable with measurements in standard yeast culture medium, implying that the overall effect of ionic strength applies for cells in nutrient-rich and nutrient-deficient media.


Asunto(s)
Adhesión Bacteriana , Saccharomyces cerevisiae , Concentración Osmolar , Tecnicas de Microbalanza del Cristal de Cuarzo , Propiedades de Superficie
5.
ACS Appl Mater Interfaces ; 12(16): 18258-18272, 2020 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-32223273

RESUMEN

Cell-material interactions are crucial for many biomedical applications, including medical implants, tissue engineering, and biosensors. For implants, while the adhesion of eukaryotic host cells is desirable, bacterial adhesion often leads to infections. Surface free energy (SFE) is an important parameter that controls short- and long-term eukaryotic and prokaryotic cell adhesion. Understanding its effect at a fundamental level is essential for designing materials that minimize bacterial adhesion. Most cell adhesion studies for implants have focused on correlating surface wettability with mammalian cell adhesion and are restricted to short-term time scales. In this work, we used quartz crystal microbalance with dissipation monitoring (QCM-D) and electrical impedance analysis to characterize the adhesion and detachment of S. cerevisiae and E. coli, serving as model eukaryotic and prokaryotic cells within extended time scales. Measurements were performed on surfaces displaying different surface energies (Au, SiO2, and silanized SiO2). Our results demonstrate that tuning the surface free energy of materials is a useful strategy for selectively promoting eukaryotic cell adhesion and preventing bacterial adhesion. Specifically, we show that under flow and steady-state conditions and within time scales up to ∼10 h, a high SFE, especially its polar component, enhances S. cerevisiae adhesion and hinders E. coli adhesion. In the long term, however, both cells tend to detach, but less detachment occurs on surfaces with a high dispersive SFE contribution. The conclusions on S. cerevisiae are also valid for a second eukaryotic cell type, being the human embryonic kidney (HEK) cells on which we performed the same analysis for comparison. Furthermore, each cell adhesion phase is associated with unique cytoskeletal viscoelastic states, which are cell-type-specific and surface free energy-dependent and provide insights into the underlying adhesion mechanisms.


Asunto(s)
Adhesión Celular/fisiología , Tecnicas de Microbalanza del Cristal de Cuarzo/métodos , Citoesqueleto/química , Citoesqueleto/fisiología , Elasticidad/fisiología , Entropía , Escherichia coli/química , Escherichia coli/fisiología , Células HEK293 , Humanos , Saccharomyces cerevisiae/química , Saccharomyces cerevisiae/fisiología , Dióxido de Silicio/química , Dióxido de Silicio/metabolismo , Viscosidad
6.
Biosens Bioelectron ; 136: 97-105, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31048213

RESUMEN

We report on a novel biomimetic sensor that allows sensitive and specific detection of Escherichia coli (E. coli) bacteria in a broad concentration range from 102 up to 106 CFU/mL in both buffer fluids and relevant food samples (i.e. apple juice). The receptors are surface-imprinted polyurethane layers deposited on stainless-steel chips. Regarding the transducer principle, the sensor measures the increase in thermal resistance between the chip and the liquid due to the presence of bacteria captured on the receptor surface. The low noise level that enables the low detection limit originates from a planar meander element that serves as both a heater and a temperature sensor. Furthermore, the experiments show that the presence of bacteria in a liquid enhances the thermal conductivity of the liquid itself. Reference tests with a set of other representative species of Enterobacteriaceae, closely related to E. coli, indicate a very low cross-sensitivity with a sensor response at or below the noise level.


Asunto(s)
Técnicas Bacteriológicas/métodos , Técnicas Biosensibles/métodos , Escherichia coli/aislamiento & purificación , Microbiología de Alimentos , Biomimética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...